PRESENTATION
The EasyLogic PM2000 series power and energy meters provide all the measurement capabilities required to monitor an electrical installation in a single 96x96 mm unit. Two variants are available with LED and LCD display options.
Characteristics
Active energy Class 0.5S as per IEC 62053-22, Active energy Class 1.0 as per IEC 62053-21
Reactive energy Class 1.0 as per IEC 62053-24 standard
Tested in accordance with IEC 62052-11 standard for 5 A, I-nominal and 1 A, I-nominal (field settable)
Active load timers monitor meter operation and Run hours, advising maintenance requirements
Field configurable password for securing setup information to prevent tampering of integrated values
Cyber security option to disable RS-485 port through front panel keys, protecting against unauthorized access, which is helpful during installation and trouble shooting of communication network
LED display: Auto scaling, 9+3 digits for energy, 4 digits for other parameters
LCD display: 6 digits with auto scaling for energy and other parameters 12 A.M. snap shot summary page stored in the meter for 24 hours
2 configurable rate counters display values in customer specified units based on energy measured
Energy preset feature for retrofit application
Optional I/O modules available: 2 Digital Inputs& 2 Outputs or 2 Analogue Inputs
& 2 Outputs for comprehensive WAGES monitoring
Mounts using two clips, no tools required
Compact size with maximum of 54 mm depth
Connectable up to 480 V ac L-L +/- 10% without voltage transformers for category III, double insulated installations
Test LED on front panel for test and calibration on site or in laboratory
Heart-beat LED indicates normal functioning and communication status if connected to RS-485 network
BENEFITS
The easy choice...
for quality - Designed and manufactured in ISO-certified Schneider Electric facilities
for value - The right balance of features and price
for peace of mind - Reliable performance where you need it
Leaner, more efficient order management thanks to field settable CT or PT ratios, modularity
Fast and efficient installation & commissioning
Safety marks for CE and UL compliance in accordance with latest IEC/UL 61010-1 Ed-3 standard
APPLICATION
Cost management application
Electrical installation remote monitoring
Energy accounting, balancing, and management
Tenant and sub-billing
Panel instrumentation
Network management applications
Power quality analysis of THD and individual harmonics up to 15th and 31st order for Volts and Amps, per-phase
Measurement of True PF and Displacement PF
Recording Min/Max values of instantaneous parameters with date & timestamp
Calculates % unbalance for voltage & current
Load management by simultaneous display of peak demands of all the four demand parameters (W, VA, VAR, Amps) with date and time of occurrence
The EasyLogic PM2000 series power and energy meters provide all the measurement capabilities required to monitor an electrical installation in a single 96x96 mm unit. Two variants are available with LED and LCD display options.
Characteristics
Active energy Class 0.5S as per IEC 62053-22, Active energy Class 1.0 as per IEC 62053-21
Reactive energy Class 1.0 as per IEC 62053-24 standard
Tested in accordance with IEC 62052-11 standard for 5 A, I-nominal and 1 A, I-nominal (field settable)
Active load timers monitor meter operation and Run hours, advising maintenance requirements
Field configurable password for securing setup information to prevent tampering of integrated values
Cyber security option to disable RS-485 port through front panel keys, protecting against unauthorized access, which is helpful during installation and trouble shooting of communication network
LED display: Auto scaling, 9+3 digits for energy, 4 digits for other parameters
LCD display: 6 digits with auto scaling for energy and other parameters 12 A.M. snap shot summary page stored in the meter for 24 hours
2 configurable rate counters display values in customer specified units based on energy measured
Energy preset feature for retrofit application
Optional I/O modules available: 2 Digital Inputs& 2 Outputs or 2 Analogue Inputs
& 2 Outputs for comprehensive WAGES monitoring
Mounts using two clips, no tools required
Compact size with maximum of 54 mm depth
Connectable up to 480 V ac L-L +/- 10% without voltage transformers for category III, double insulated installations
Test LED on front panel for test and calibration on site or in laboratory
Heart-beat LED indicates normal functioning and communication status if connected to RS-485 network
BENEFITS
The easy choice...
for quality - Designed and manufactured in ISO-certified Schneider Electric facilities
for value - The right balance of features and price
for peace of mind - Reliable performance where you need it
Leaner, more efficient order management thanks to field settable CT or PT ratios, modularity
Fast and efficient installation & commissioning
Safety marks for CE and UL compliance in accordance with latest IEC/UL 61010-1 Ed-3 standard
APPLICATION
Cost management application
Electrical installation remote monitoring
Energy accounting, balancing, and management
Tenant and sub-billing
Panel instrumentation
Network management applications
Power quality analysis of THD and individual harmonics up to 15th and 31st order for Volts and Amps, per-phase
Measurement of True PF and Displacement PF
Recording Min/Max values of instantaneous parameters with date & timestamp
Calculates % unbalance for voltage & current
Load management by simultaneous display of peak demands of all the four demand parameters (W, VA, VAR, Amps) with date and time of occurrence
Call us :
PT. OODS ERA MANDIRI
Address :
1. Jl. Abulyatama, komplek Ruko
Manalagi Blok C no 10, Batam Kota, 29464, Kepulauan Riau, Indonesia
2. Jl. Duta Boulevart Barat, Ruko D-Smart Blok F no 31, Duta
Harapan Bekasi, Jakarta, Indonesia
Telp : +62 778-475-467 (Batam) , +62 21-8889-6442 (Jakarta)
Sales Number :
082173332233
082288303338
085836000151
Email : oodsgroups@gmail.com
Website : www.oodsgroups.com
IG: oodsgroups
FB: oods era mandiri
Linked : Oods Era Mandiri